| Water treatment |
| |
|
COOLING WATER
TREATMENT CHEMICALS |
Used by various sectors like power generation,
Petrochemicals, Fertilizers & Refineries, Locomotives
/ Automobiles, etc. |
| |

|
ANTISCALENT &
DISPERSANT – a specially designed unique
formulation for scale inhibition. It is a
powerful dispersant & antiscalant agent
especially customised for the control of scale,
deposition & fouling in recirculating cooling
water system. It has a very strong dispersing
ability that enables the easy dispersion of
insoluble particulate matter like clay, mud,
silt, etc. and prevents their accumulation in
low velocity areas. It effectively prevents Ca,
Mg & Zn phosphate scales. |
 |
CORROSION &
SCALE INHIBITOR - a specially designed
unique formulation for corrosion & scale
inhibition. It is a blend of cathodic & anodic
inhibitors to controls corrosion of multi-metals
in cooling water systems. It also eliminates
scale formation on heat transfer surfaces of
cooling water system due to the combined effect
of antiscalant & powerful dispersant. |
 |
BIODISPERSANT – a specially formulated
product to control slime formation on surfaces
of cooling water cooling water system and to
optimize heat transfer capacity by keeping the
heat transfer surfaces clean. It contains
non-ionic surfactants alongwith solubilizing &
penetrating agents. It improves the performance
of chlorine & non-oxidizing biocides by removing
and dispersing slime & deposits thereby exposing
trapped microorganisms. It is non-toxic &
non-polluting and also has no chlorine demand.
|

|
BIOCIDE –
A range of biocides to control microbial growth
observed in the cooling water system. It is a
wide spectrum biocide to be used to control
algal, bacterial and fungal growth in cooling
water systems. It also controls Anaerobic
bacteria like Sulphate reducing bacteria, etc. |
 |
 |
POLYMER –
It is based on organic polymer for nil phosphate
system designed to eliminate scale formation on
the heat transfer surfaces under cooling water
conditions. It also contains powerful deposit
controller which disperses suspended matter and
is removed during normal blowdown. |
 |
CORROSION
INHIBITOR FOR CLOSE LOOP CIRCUIT - It is
available in borate nitrate based & borate free
formulation for the closed loop systems. It is
specially formulated with new generation
chemicals to control corrosion of multimetal
systems. It also contains low molecular weight,
multifunctional polycarbonxylates alongwith
organic antiscalent to efficiently control
corrosion and scale deposits on heat transfer
surfaces. |
|
* We also undertake toll manufacturing & can suggest
suitable treatment programme at extremely competitive
rates. For further details, kindly contact us.
* detailed literature is available to actual end users
|
| |
| |
|
LIST OF CUSTOMERS |
Used by various sectors like power generation,
Petrochemicals, Fertilizers & Refineries, Locomotives
/ Automobiles, etc. |
| |
 |
ANDHRA PRADESH POWER GENERATION CORPORATION
RAYALSEEMA THERMAL POWER PLANT, RAYALSEEMA
- Capacity : 210 MW x 2 units
- Circulating Rate : 32,000 m3/hr/unit x 2
- Challenges faced : Very high alkalinity & without Sulphuric acid. Seasonal variations in water parameters.
P. Alkalinity : 2 – 10 ppm
M. Alkalinity : 180 – 260 ppm
- Remedies : Good Antiscalant phosphate & polymer based good micro biocide to control the system upsets
|
| |
|
 |
GUJARAT ELECTRICITY BOARD
DHUVARAN THERMAL POWER STATION
- Capacity : 140 MW x 2 units
- Circulating Rate : 16,500 m3/hr/unit x 2
- Challenges faced : Very high conductivity, chloride, hardness, water is highly scaly & corrosive in nature
Conductivity : 10270 – 32300 mmhos/cm
Chloride : 15000 – 20000 ppm
Total hardness : 4640 – 6200 ppm
Calcium hardness: 1320 – 1600 ppm
- Remedies : We have given blend of Antiscalant & Corrosion Inhibitor
WANAKBORI THERMAL POWER STATION
- Capacity – 210 MW x 7 units
GANDHINAGAR THERMAL POWER STATION
- Capacity – 210 MW x 3 units
120 MW x 2 units
UTRAN THERMAL POWER STATION
- Capacity – 140 MW x 1 unit
|
| |
|
 |
HINDUSTAN ORGANICS CHEMICAL LTD
- Challenges faced: Make-up water contaminated with sewage water having very fouled system with microbiological attack.
- Remedies: We have treated the system with special biocide (Broad spectrum) with good biodespersant.
- Achievement: System is running without any problem since last two years
|
| |
|
 |
NEYVELI LIGNITE CORPORATION LTD
- Capacity : TPS I (210 MW x 1 )
TPS II Stage II (210 MW x 4)
- Circulating Rate : 29,000 m3/hr/unit x 4
- Challenges faced : High hardness & alkalinity in mine make-up water
Total Hardness : 260 – 290 ppm
Calcium Hardness : 210 – 250 ppm
Total Alkalinity : 260 – 290 ppm
- Remedies : Strong polymeric formulation specially made to tackle the problems to achieve better results.
|
| |
|
 |
NATIONAL THERMAL POWER CORPORATION
- RAMAGUNDAM THERMAL POWER STATION, RAMAGUNDAM
|
| |
|
 |
PONDICHERRY POWER CORPORATION LTD.
- Capacity : 65 MW x 1 unit
- Circulating Rate : 3,600 m3/hr
- Challenges faced : make-up water, high alkalinity, high chloride, TDS, high conductivity, water is highly corrosive in nature, COC is ‘ 3 ’
Alkalinity : 250 – 330 ppm
Chloride : 720 ppm
TDS : 1900 ppm
Conductivity : 2900 mmhos/cm
- Remedies : 1) Very good Corrosion Inhibitor formulation
2) Biodespersant dosing
3) Antiscalant with dispersants formulation
|
| |
|
 |
KARNATAKA POWER CORPORATION LTD
RAICHUR THERMAL POWER STATION, RAICHUR
- Capacity : 210 MW x 7 units
- Circulating Rate : 30,500 m3/hr/unit x 7
- Challenges faced : Make-up water having very high turbidity around 2000 NTU
- Remedies : We have given special dispersant grade polymer
|
| |
|
 |
GAIL (INDIA ) LTD
|
| |
|
|
|
|